Quantcast
Channel: VMware Communities : Unanswered Discussions - VMTN
Viewing all 61567 articles
Browse latest View live

vSphere HA 5 Election Process and vCenter Server

$
0
0

Dear Folks,

 

Please help me to clarify the following doubts with vSphere HA 5.

 

For election process i understand it elect master based on maximum datastore visibility. Else it will check MOID of hosts (as per my knowledge this id will be identified from vCenter at the time of election process). Which means vCenter is getting involved in electing master. Please correct me if im wrong.

 

Now talking about Master ESXi server, he is the one responsible for initiated failover if any slave ESXi failed (lets assume power failure).

 

But if master ESXi itself failed, before the VM can be failovered to other hosts, election process must be held to choose the master accross available slaves. Once master has been elected the failover will be initiated. Again correct me if I'm wrong.

 

So Lets consider the following scenario:

 

I have 3 node ESXi cluster. Now in this cluster host 1 is my master server which is also hosting vCenter Virtual Machine.

 

In this case if the host 1 (master hosting vcenter vm also) failed, my entire cluster will go down? as to choose the master accross available slave node it is not possible as the vCenter also failed with my master host??

 

PLEASE NOTE I'M NOT SAYING IF VCENTER IS DOWN MY CLUSTER WILL NOT WORK. BUT I'M DOUBTING IF MASTER NODE FAILS ALONG WITH VCETNER THEN MY CLUSTER COULD GO DOWN!!!!

 

If i have not clearly explained the scneario please let me know i can clarify further. Please help me to clarify this doubt..

 

This doubt even I couldn't get clarified in my VCP training itself

 

Thanks a lot...

 

hari.


Physical disk speed is chastening

$
0
0

Hi together!

 

I need to add a physical disk (eSATA) to a Ubuntu VM to access the data on it. It works cute so far but the sequential transfer speed (read) doesn't exceed ~25MB/s. I've also tested another hdd with a XP VM and the results are equal.

 

Any suggestions how to break this limit?

Thinapp and Windows 8

$
0
0

Hi,

 

I try to thinapp few applications in Windows Server 8 Beta and all fails (error in attach).

Packages was made under Windows 2003/2008 don't run.

Maybe somebody had the same issue and resolve it?

Will VMWARE support Thinapp in Windows 8?

 

Thanks

Sample Code to test VIX install

$
0
0

#include "vix.h"

#include <stdlib.h>

#include <stdio.h>

VixHandle hostHandle = VIX_API_VERSION;

VixHandle jobHandle = VIX_INVALID_HANDLE;
VixError err;
jobHandle = VixHost_Connect(VIX_API_VERSION,
VIX_SERVICEPROVIDER_VMWARE_SERVER,
host, // hostName
0, // hostPort
user, // userName
password, // password,
0, // options
VIX_INVALID_HANDLE, // propertyListHandle
NULL, // callbackProc
NULL); // clientData
err = VixJob_Wait(jobHandle,
VIX_PROPERTY_JOB_RESULT_HANDLE,
&hostHandle,
VIX_PROPERTY_NONE);
if (VIX_OK != err) {
// Handle the error...
Vix_ReleaseHandle(jobHandle);
VixHost_Disconnect(hostHandle);
}
printf("Connected to local host.\n");
when i compile the code
it nootify

/home/david/Development/workspace/VIXTest/Debug/../src/Connection.c:21: undefined reference to `VixHost_Connect'

/home/david/Development/workspace/VIXTest/Debug/../src/Connection.c:31: undefined reference to `VixJob_Wait'

/home/david/Development/workspace/VIXTest/Debug/../src/Connection.c:37: undefined reference to `Vix_ReleaseHandle'

/home/david/Development/workspace/VIXTest/Debug/../src/Connection.c:38: undefined reference to `VixHost_Disconnect'

I know that is mean the function is not defined.

but that should be defined as the api.......

Any can tell me how to solution the problem???

Thank

Encounter an issue vmware-vcd-cell is dead, but pidfile exsits, when try to visit vcloud web portal

$
0
0

Hi there,

 

I've met some problem when running the vCloud director 1.5. When I was trying to visit the https://10.4.55.223, and then the vmware-vcd-cell was dead, but pidfile exsits.

 

Here I found the log in cell.log. Please anyone gives me some help. Thanks.

 

Application startup begins: 7/6/12 5:05 PM
Successfully bound network port: 80 on host address: 10.4.55.223
Successfully bound network port: 443 on host address: 10.4.55.223
Application Initialization: 9% complete. Subsystem 'com.vmware.vcloud.common.core' started
Successfully connected to database: jdbc:jtds:sqlserver://10.4.55.249:1433/vcloud;socketTimeout=90
Current locale "en" verified successfully.
Successfully bound network port: 443 on host address: 10.4.55.250
Successfully bound network port: 61616 on host address: 10.4.55.223
Successfully bound network port: 61613 on host address: 10.4.55.223
Application Initialization: 18% complete. Subsystem 'com.vmware.vcloud.vlsi-core' started
Uncaught Exception. Originating thread: Thread[SpringOsgiExtenderThread-8,5,spring-osgi-extender[2dabcea]-threads]. Message: Error creating bean with name 'hibernateCacheRegions': Cannot create inner bean 'abstractReplicatedCache$child#282f0e07' of type [com.vmware.vcloud.common.ehcache.ReplicatedEhCacheFactoryBean] while setting bean property 'sourceList' with key [0]; nested exception is org.springframework.beans.factory.BeanCreationException: Error creating bean with name 'abstractReplicatedCache$child#282f0e07' defined in URL [bundleentry://169.fwk1118421150/META-INF/spring/common-persist-context-cache.xml]: Cannot resolve reference to bean 'cacheManager' while setting bean property 'cacheManager'; nested exception is org.springframework.beans.factory.BeanCreationException: Error creating bean with name 'cacheManager' defined in URL [bundleentry://169.fwk1118421150/META-INF/spring/common-persist-context.xml]: Invocation of init method failed; nested exception is net.sf.ehcache.CacheException: Problem creating connections: Error decrypting data.
Application shutdown event: Beginning
Application shutdown event: Application stop requested. Shutting down.

Suddenly has 100% CPU -> Nuisance freezes -/- CPU d'un coup a 100% -> Puis un court freeze

$
0
0

Hello

 

I have version 8 of VM Ware Workstation. I installed a legal version of Windows Seven and Windows XP. The problem is that I have freezes, they do not last long but are quite annoying.

 

I have 6 GB of RAM and an i7 930. I noticed these freezes corresponded to a sudden increase in CPU utilization on the virtual machine, it rises at once to 100% then back down normally ....

 

A friend of mine also has this problem ....

 

How to remedy it? There was there a specific option?

 

Thank you for reading, I wish you a good day

 

 

 

 

Bonjour

 

Je possède la version 8 de VM Ware Workstation. J'ai installé une version legale de Windows Seven et de Windows XP. Le problème est que j'ai des freezes, ils ne durent pas longtemps mais sont assez genants.

 

Je possède 6 Go de RAM et un i7 930. J'ai remarqué que ces freezes correspondaient a une soudaine augmentation de l'utilisation de l'UC sur la machine virtuelle, il monte d'un coup a 100% puis il redescend normalement....

 

Un de mes amis possède egalement ce problème....

 

Comment y remedier ? Il y a t-il une option spécifique ?

 

Merci de m'avoir lu, je vous souhaites une bonne journée

How To Recover From Misplaced VMs in vCloud 1.5

boot from mounted hhd

$
0
0

I was wondering if some one could help me  out, I have an back up of a hard drive that I did with acronis,  however I was wondering if I could use vmware to boot into to it. I try converting to to an vhd from acronis however I get an error. But I am able to mount the image to the computer so I was wondering is there a way to make vmware choice the mounted hard drive as the boot hard drivd?..   See I need to get a form  thats on my computer only problem is that in order to do that I need to open a software  and extract it, there is no other way of doing it.


How to upload patch ?

$
0
0

Hi

 

Been advised to upload the 2.3.2 patch to the root of the UM but how do I do this?

 

WinSCP won't work as port 22 isn't open

 

Thanks

Windows 2000 Server Failing

$
0
0

Hi,

 

I'm trying to P2V a windows 2000 web server that is located on our DMZ.

 

I think I have opened up the necessary ports however the converter fails after about a minute with error FAILED: agent.internal.fault.PlatformError.summary

 

Logs are attached.

 

Thanks

VDR email reports - how to set AM/PM time

$
0
0

We're running 2.0 version of VDR with built in email reports.

When I want to set the time that a report needs to be sent I can only set the range between 01:00 - 12:00.

How can I indicate AM/PM.

I'd like the reports to be genrated at 16:00h.

 

Thanks,

Filip

Copy-VMGuestFile fails with error after vCenter Upgrade

$
0
0

Hello,

 

we are using PowerCLI scripts for deploying virtual machines. After updating to vCenter 5 the cmdlet is reporting the message below. We didn’t find any information about this message in your KB and in the internet (community etc.):

 

„The Operation is not supported on this object” -> in the original message below you find the german version "Der Vorgang wird für dieses Objekt nicht unterstützt".

 

Cause our Windows Server deployment isn’t possible in the known PowerCLI way at the moment is there anyone who is able to give me an information what solves this error?

 

PowerCLI Version 5.0.1

Windows Server 2008R2

vCenter 5.0 u1

ESXi 4.1 u1

 

Thanks in advance

 

___

 

Copy-VMGuestFile -Source 'c:\scripts\online_hotplug_memory.sh' -Destination 'c:\install' -VM vmname -LocalToGuest -HostUser r

oot -HostPassword PW -GuestUser administrator -GuestPassword PW -verbose

AUSFÜHRLICH: 04.07.2012 10:16:20 Copy-VMGuestFile Started execution

AUSFÜHRLICH: Copying source file 'c:\scripts\online_hotplug_memory.sh' from host to destination 'c:\install' on VM 'vmname'.

Copy-VMGuestFile : 04.07.2012 10:16:26 Copy-VMGuestFile Der Vorgang wird für dieses Objekt nicht unterstützt.

Bei Zeile:1 Zeichen:17

+ Copy-VMGuestFile <<<< -Source 'c:\scripts\online_hotplug_memory.sh' -Destination 'c:\install' -VM vmname -LocalToGuest -HostUser root -HostPassword PWPWPW -GuestUser administrator -GuestPassw

ord PWPWPW -verbose

+ CategoryInfo : NotSpecified: (:) [Copy-VMGuestFile], NotSupported

+ FullyQualifiedErrorId : Client20_VmGuestServiceImpl_DirectoryExistsInGuest_ViError,VMware.VimAutomation.ViCore.Cmdlets.Commands.CopyVMGuestFile

___

Automating configuration of VUM via PowerCLI / PowerShell? Impossible?

$
0
0

The original VUM cmdlets provided the commands "get-vumconfig" and "set-vumconfig", allowing one to register the VUM plugin and then configure (mostly) it from a script.

 

Can this be done? I have looked for registry entries on the vCenter (VUM is installed on a seperate server) but I can't locate any hint of the plugin config there. It's infuriating!  How can one, for example, remotely control the location of UMDS servers and enable or disable VUM patch downloads via PowerShell?

 

I really hope someone can shed some light on this because after 3+ days of searching I have precisely nothing.

 

Many thanks to whomever can help.

 

Stephen

Sudden decrease of VM performance

$
0
0

Hi all,

 

I am quite a newbie with vmware ESXi and today something strange happened to me. I am running only one VM for test purposes in one host. This VM uses Windows server 2003 as the OS. I have been working with that VM for weeks without any problem. I usually open a Console with vCenter to work on it. Today, suddenly, the mouse inside the VM started to go really slow and at the end I could not even move it. If I clicked something it took around a minute to actually click inside the VM. I powered it off and on and it took almost 10 minutes to boot! (normally it takes less than a minute). I have been checking in vCenter the performance and everything is normal and no limits are reached.

 

If that same VM is migrated to another host, everything works perfectly, without any problem. As soon as it goes back to the previous host, it is annoyingly slow. I tried to ping it to check if the network was the problem but I get 1 ms of latency. The storage should not be the problem since I am accessing to the same storage in both hosts over the same ports.

 

Does anyone have a clue what could be happening or where should I look to get more information?

 

Thanks!

php sdk: Can't get vapp by id

$
0
0

Hi,

 

We have switched from using the Java SDK due to its slow login times, so have moved to php.

 

The problem is there doesn't seem to be equivalent functions in the PHP SDK. eg

 

We want to minimize the amount of input we give to tools / scripts, so to power on a vapp for example, all we want to give as input is the vapp id without having to specify everything like the vdc name, org name etc.

 

Is there any documentation on how to do this, ie do the following Java code, in php, the only input being the vappId (urn:vcloud:vapp:xxxxxxxx)

 

Vapp vapp = Vapp.getVappById(vcloudClient, vappId);

 

Regards,

Mark


zone firewall rules

$
0
0

I have installed vshield zone. i want to set some firewall rules to control the traffic. but i am afraid to do that, because sometimes it may affect to the existing network communication. so can anybody give me instructions on creating basic firewall rules?

 

thanks

DotNet C# Sample - SSL3_GET_RECORD:wrong version number

$
0
0

Hi,

 

using Converter 5.0.0-470252 and SDK 5.0.0-470252

 

I try running the DotNet Sample from the SDK.

 

I used two ways:

* Windows XP SP3 with VS2005 and .Net 2.0

* Windows 7 SP1 with VS2010 SP1 and .Net 4.0

 

I get following runtime error and can not send any jobs to the conversion server:

 

Caught SoapException -  Actor :  Code : ServerFaultCode Detail XML : <detail><Sy
stemErrorFault xmlns="urn:converter" xsi:type="vim25:SystemError" xmlns:vim25="u
rn:vim25" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"><vim25:reason>SS
L Exception: error:1408F10B:SSL routines:SSL3_GET_RECORD:wrong version number</v
im25:reason></SystemErrorFault></detail>
ERROR: Failed to submit P2V Conversion Job.

 

I tried running the server on http as a workaround which I could not solve doing.

 

I did changing the server configuration at C:\ProgramData\VMware\VMware vCenter Converter Standalone\converter-server.xml and restarting the Server-Service

- ssl node section can not be removed as told -> service will not restart

- ssl subnodes removed, server took default certs -> it still tried running ssl on somewhere defined certs?

- all usessl properties turned to false -> server still wanted to use certs ... ?

- I generated and trusted self signed certs for server (since the delivered one will not work at all), did not solve the problem but cert problem went away

- tried managing the endpoints (e) using httpOnly or httpAndHttps ...

- tried putting debug to logging property -> log said it does not understand debug

- taking away ports for 443 did not work

 

- Firewall on the server is turned of

 

How and where can I change the SSL version?

How can I modify the server config to run in http mode?

How can I send a job running using a commandline tool or the Soap-Interfaces?

 

Regards.

Disk thrashing on Host and poor guest performance

$
0
0

Hi all

 

We have a Windows 2008 R2 Enterprise x64 host with 48GB memory, First data partition is 375GB (RAID1 120GB free) and second is 558GB (RAID1 50GB free)

Windows is managing the paging file and has set a 50GB pagefile on each data partition.

VMware server has 40GB reserved and is set to fit all virtual machine memory into reserved host ram.

 

We currently have 8 VMs running without an issue, using 32GB

 

When we start up a 9th, it takes a long time to load up and there is a significant amount of Hard Faults/sec that eventually recede to zero (after about 15/20 minutes) but performance of the 9th and the other VMs is affected - high CPU and poor overall performance exhibited as websites are slow to respond and timeout.

 

During all this the host CPU is not stressed

 

The VM starting up runs perfectly fine on my local machine using VMware player, and is a sysprepped image of the the other VMs.

 

Does anyone have any observations on why the disk thrashing is occuring and what I can do to remedy it?

 

Thanks

I do not see reconnected storage in 'Datastores' but see it in 'Devices'. No supported identifier types found in VPD

$
0
0

Hello dears

 

In general after starting server i cannot see my raid storage in 'Storages' in ESXi 5.0

 

Step by step description:

 

  1. Server was started from ssd disk w/o storage (cause of bug failure of RAID controller).
  2. After fixing this and with raid in Online state (w/o rebuild and so on) i have this in devices tab (so device is mounted):
    vmware.jpg

    But a dont see my store in datastores view
  3. Inspecting log for vmhba2…
    $ more /var/log/vmkernel.log | grep vmhba2
    And getting this:
    2012-07-06T07:47:12.071Z cpu9:2642)ScsiPath: 4541: Plugin 'NMP' claimed path 'vmhba2:C0:T8:L0'

2012-07-06T07:47:12.071Z cpu9:2642)ScsiPath: 4541: Plugin 'NMP' claimed path 'vmhba2:C2:T0:L0'

2012-07-06T07:47:12.071Z cpu9:2642)ScsiPath: 4541: Plugin 'NMP' claimed path 'vmhba2:C0:T9:L0'

2012-07-06T07:47:12.076Z cpu9:2642)ScsiUid: 177: Failed to create uid for path vmhba2:C0:T9:L0: No supported identifier types found in VPD device id page

2012-07-06T07:47:12.077Z cpu9:2642)VMWARE SCSI Id: Could not get disk id for vmhba2:C0:T9:L0

2012-07-06T07:47:12.077Z cpu9:2642)vmw_psp_fixed: psp_fixedSelectPathToActivateInt:479: Changing active path from NONE to vmhba2:C0:T9:L0 for device "Unregistered Device".

2012-07-06T07:47:12.079Z cpu0:2642)VMWARE SCSI Id: Could not get disk id for vmhba2:C0:T9:L0

2012-07-06T07:47:12.079Z cpu0:2642)ScsiDeviceIO: 7000: Get VPD 80 Inquiry for device "mpx.vmhba2:C0:T9:L0" from Plugin "NMP" failed. Not supported

2012-07-06T07:47:12.080Z cpu0:2642)ScsiDeviceIO: 5826: Could not detect setting of QErr for device mpx.vmhba2:C0:T9:L0. Error Not supported.

2012-07-06T07:47:12.081Z cpu10:2058)NMP: nmp_ThrottleLogForDevice:2318: Cmd 0x1a (0x4124007ce9c0, 0) to dev "mpx.vmhba2:C0:T9:L0" on path "vmhba2:C0:T9:L0" Failed: H:0x0 D:0x2 P:0x0 Valid sense data: 0x5 0x20 0x0. Act:NONE

2012-07-06T07:47:12.081Z cpu10:2058)ScsiDeviceIO: 2322: Cmd(0x4124007ce9c0) 0x1a, CmdSN 0x1 from world 0 to dev "mpx.vmhba2:C0:T9:L0" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x5 0x20 0x0.

2012-07-06T07:47:12.081Z cpu0:2642)ScsiDevice: 3121: Successfully registered device "mpx.vmhba2:C0:T9:L0" from plugin "NMP" of type 13

2012-07-06T07:47:12.081Z cpu0:2642)vmw_psp_fixed: psp_fixedSelectPathToActivateInt:479: Changing active path from NONE to vmhba2:C2:T0:L0 for device "Unregistered Device".

2012-07-06T07:47:12.081Z cpu11:2642)VMWARE SCSI Id: Id for vmhba2:C2:T0:L0

2012-07-06T07:47:12.105Z cpu0:2642)ScsiUid: 177: Failed to create uid for path vmhba2:C0:T8:L0: No supported identifier types found in VPD device id page

2012-07-06T07:47:12.106Z cpu10:2642)VMWARE SCSI Id: Could not get disk id for vmhba2:C0:T8:L0

2012-07-06T07:47:12.106Z cpu10:2642)vmw_psp_fixed: psp_fixedSelectPathToActivateInt:479: Changing active path from NONE to vmhba2:C0:T8:L0 for device "Unregistered Device".

2012-07-06T07:47:12.108Z cpu10:2642)VMWARE SCSI Id: Could not get disk id for vmhba2:C0:T8:L0

2012-07-06T07:47:12.108Z cpu10:2642)ScsiDeviceIO: 7000: Get VPD 80 Inquiry for device "mpx.vmhba2:C0:T8:L0" from Plugin "NMP" failed. Not supported

2012-07-06T07:47:12.109Z cpu10:2642)ScsiDeviceIO: 5826: Could not detect setting of QErr for device mpx.vmhba2:C0:T8:L0. Error Not supported.

2012-07-06T07:47:12.110Z cpu4:2052)NMP: nmp_ThrottleLogForDevice:2318: Cmd 0x1a (0x4124007c6d00, 0) to dev "mpx.vmhba2:C0:T8:L0" on path "vmhba2:C0:T8:L0" Failed: H:0x0 D:0x2 P:0x0 Valid sense data: 0x5 0x20 0x0. Act:NONE

2012-07-06T07:47:12.110Z cpu4:2052)ScsiDeviceIO: 2322: Cmd(0x4124007c6d00) 0x1a, CmdSN 0x68 from world 0 to dev "mpx.vmhba2:C0:T8:L0" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x5 0x20 0x0.

2012-07-06T07:47:12.110Z cpu10:2642)ScsiDevice: 3121: Successfully registered device "mpx.vmhba2:C0:T8:L0" from plugin "NMP" of type 13

2012-07-06T07:47:18.515Z cpu6:2762)ScsiScan: 1098: Path 'vmhba2:C0:T10:L0': Vendor: 'ATA     '  Model: 'WDC WD6000HLHX-0'  Rev: '5G04'

2012-07-06T07:47:18.515Z cpu6:2762)ScsiScan: 1101: Path 'vmhba2:C0:T10:L0': Type: 0x0, ANSI rev: 5, TPGS: 0 (none)

2012-07-06T07:47:18.522Z cpu6:2762)WARNING: ScsiScan: 1485: Failed to add path vmhba2:C0:T10:L0 : Not found

2012-07-06T07:47:18.524Z cpu9:2762)ScsiScan: 1098: Path 'vmhba2:C0:T11:L0': Vendor: 'ATA     '  Model: 'WDC WD6000HLHX-0'  Rev: '5G04'

2012-07-06T07:47:18.524Z cpu9:2762)ScsiScan: 1101: Path 'vmhba2:C0:T11:L0': Type: 0x0, ANSI rev: 5, TPGS: 0 (none)

2012-07-06T07:47:18.533Z cpu9:2762)WARNING: ScsiScan: 1485: Failed to add path vmhba2:C0:T11:L0 : Not found

2012-07-06T07:47:18.535Z cpu7:2762)ScsiScan: 1098: Path 'vmhba2:C0:T12:L0': Vendor: 'ATA     '  Model: 'WDC WD6000HLHX-0'  Rev: '5G04'

2012-07-06T07:47:18.535Z cpu7:2762)ScsiScan: 1101: Path 'vmhba2:C0:T12:L0': Type: 0x0, ANSI rev: 5, TPGS: 0 (none)

2012-07-06T07:47:18.538Z cpu7:2762)WARNING: ScsiScan: 1485: Failed to add path vmhba2:C0:T12:L0 : Not found

2012-07-06T07:47:18.540Z cpu9:2762)ScsiScan: 1098: Path 'vmhba2:C0:T13:L0': Vendor: 'ATA     '  Model: 'WDC WD6000HLHX-0'  Rev: '5G04'

2012-07-06T07:47:18.540Z cpu9:2762)ScsiScan: 1101: Path 'vmhba2:C0:T13:L0': Type: 0x0, ANSI rev: 5, TPGS: 0 (none)

2012-07-06T07:47:18.546Z cpu9:2762)WARNING: ScsiScan: 1485: Failed to add path vmhba2:C0:T13:L0 : Not found

2012-07-06T07:47:18.548Z cpu7:2762)ScsiScan: 1098: Path 'vmhba2:C0:T14:L0': Vendor: 'ATA     '  Model: 'WDC WD6000HLHX-0'  Rev: '5G04'

2012-07-06T07:47:18.548Z cpu7:2762)ScsiScan: 1101: Path 'vmhba2:C0:T14:L0': Type: 0x0, ANSI rev: 5, TPGS: 0 (none)

2012-07-06T07:47:18.558Z cpu7:2762)WARNING: ScsiScan: 1485: Failed to add path vmhba2:C0:T14:L0 : Not found

2012-07-06T07:47:18.561Z cpu9:2762)ScsiScan: 1098: Path 'vmhba2:C0:T15:L0': Vendor: 'ATA     '  Model: 'WDC WD6000HLHX-0'  Rev: '5G04'

2012-07-06T07:47:18.561Z cpu9:2762)ScsiScan: 1101: Path 'vmhba2:C0:T15:L0': Type: 0x0, ANSI rev: 5, TPGS: 0 (none)

2012-07-06T07:47:18.570Z cpu9:2762)WARNING: ScsiScan: 1485: Failed to add path vmhba2:C0:T15:L0 : Not found

2012-07-06T07:47:18.572Z cpu9:2762)ScsiScan: 1098: Path 'vmhba2:C0:T16:L0': Vendor: 'ATA     '  Model: 'WDC WD6000HLHX-0'  Rev: '5G04'

2012-07-06T07:47:18.572Z cpu9:2762)ScsiScan: 1101: Path 'vmhba2:C0:T16:L0': Type: 0x0, ANSI rev: 5, TPGS: 0 (none)

2012-07-06T07:47:18.578Z cpu9:2762)WARNING: ScsiScan: 1485: Failed to add path vmhba2:C0:T16:L0 : Not found

2012-07-06T07:47:18.581Z cpu9:2762)ScsiScan: 1098: Path 'vmhba2:C0:T17:L0': Vendor: 'ATA     '  Model: 'WDC WD6000HLHX-0'  Rev: '5G04'

2012-07-06T07:47:18.581Z cpu9:2762)ScsiScan: 1101: Path 'vmhba2:C0:T17:L0': Type: 0x0, ANSI rev: 5, TPGS: 0 (none)

2012-07-06T07:47:18.589Z cpu9:2762)WARNING: ScsiScan: 1485: Failed to add path vmhba2:C0:T17:L0 : Not found

2012-07-06T07:47:18.592Z cpu9:2762)ScsiScan: 1098: Path 'vmhba2:C0:T18:L0': Vendor: 'ATA     '  Model: 'WDC WD6000HLHX-0'  Rev: '5G04'

2012-07-06T07:47:18.592Z cpu9:2762)ScsiScan: 1101: Path 'vmhba2:C0:T18:L0': Type: 0x0, ANSI rev: 5, TPGS: 0 (none)

2012-07-06T07:47:18.600Z cpu9:2762)WARNING: ScsiScan: 1485: Failed to add path vmhba2:C0:T18:L0 : Not found

2012-07-06T07:47:18.602Z cpu9:2762)ScsiScan: 1098: Path 'vmhba2:C0:T19:L0': Vendor: 'ATA     '  Model: 'WDC WD6000HLHX-0'  Rev: '5G04'

2012-07-06T07:47:18.602Z cpu9:2762)ScsiScan: 1101: Path 'vmhba2:C0:T19:L0': Type: 0x0, ANSI rev: 5, TPGS: 0 (none)

2012-07-06T07:47:18.611Z cpu9:2762)WARNING: ScsiScan: 1485: Failed to add path vmhba2:C0:T19:L0 : Not found

2012-07-06T07:47:18.614Z cpu9:2762)ScsiScan: 1098: Path 'vmhba2:C0:T20:L0': Vendor: 'ATA     '  Model: 'WDC WD6000HLHX-0'  Rev: '5G04'

2012-07-06T07:47:18.614Z cpu9:2762)ScsiScan: 1101: Path 'vmhba2:C0:T20:L0': Type: 0x0, ANSI rev: 5, TPGS: 0 (none)

2012-07-06T07:47:18.623Z cpu9:2762)WARNING: ScsiScan: 1485: Failed to add path vmhba2:C0:T20:L0 : Not found

2012-07-06T07:47:18.625Z cpu9:2762)ScsiScan: 1098: Path 'vmhba2:C0:T21:L0': Vendor: 'ATA     '  Model: 'WDC WD6000HLHX-0'  Rev: '5G04'

2012-07-06T07:47:18.625Z cpu9:2762)ScsiScan: 1101: Path 'vmhba2:C0:T21:L0': Type: 0x0, ANSI rev: 5, TPGS: 0 (none)

2012-07-06T07:47:18.633Z cpu9:2762)WARNING: ScsiScan: 1485: Failed to add path vmhba2:C0:T21:L0 : Not found

2012-07-06T07:47:18.636Z cpu9:2762)ScsiScan: 1098: Path 'vmhba2:C0:T22:L0': Vendor: 'ATA     '  Model: 'WDC WD6000HLHX-0'  Rev: '5G04'

2012-07-06T07:47:18.636Z cpu9:2762)ScsiScan: 1101: Path 'vmhba2:C0:T22:L0': Type: 0x0, ANSI rev: 5, TPGS: 0 (none)

2012-07-06T07:47:18.646Z cpu9:2762)WARNING: ScsiScan: 1485: Failed to add path vmhba2:C0:T22:L0 : Not found

2012-07-06T07:47:18.648Z cpu9:2762)ScsiScan: 1098: Path 'vmhba2:C0:T23:L0': Vendor: 'ATA     '  Model: 'WDC WD6000HLHX-0'  Rev: '5G04'

2012-07-06T07:47:18.648Z cpu9:2762)ScsiScan: 1101: Path 'vmhba2:C0:T23:L0': Type: 0x0, ANSI rev: 5, TPGS: 0 (none)

2012-07-06T07:47:18.654Z cpu9:2762)WARNING: ScsiScan: 1485: Failed to add path vmhba2:C0:T23:L0 : Not found

2012-07-06T07:47:18.657Z cpu9:2762)ScsiScan: 1098: Path 'vmhba2:C0:T25:L0': Vendor: 'ATA     '  Model: 'WDC WD6000HLHX-0'  Rev: '5G04'

2012-07-06T07:47:18.657Z cpu9:2762)ScsiScan: 1101: Path 'vmhba2:C0:T25:L0': Type: 0x0, ANSI rev: 5, TPGS: 0 (none)

2012-07-06T07:47:18.666Z cpu9:2762)WARNING: ScsiScan: 1485: Failed to add path vmhba2:C0:T25:L0 : Not found

2012-07-06T07:47:18.689Z cpu2:2190)ScsiUid: 177: Failed to create uid for path vmhba2:C0:T8:L0: No supported identifier types found in VPD device id page

2012-07-06T07:47:18.689Z cpu10:2192)ScsiUid: 177: Failed to create uid for path vmhba2:C0:T9:L0: No supported identifier types found in VPD device id page

2012-07-06T07:47:18.690Z cpu10:2192)VMWARE SCSI Id: Could not get disk id for vmhba2:C0:T9:L0

2012-07-06T07:47:18.690Z cpu9:2190)VMWARE SCSI Id: Could not get disk id for vmhba2:C0:T8:L0

4. Running parted ti check if everything is ok:
# partedUtil getptbl /vmfs/devices/disks/naa.600605b0037e874016c58d362843a979

gpt

874743 255 63 14052753408

1 2048 14052746294 AA31E02A400F11DB9590000C2911D1B8 vmfs 0
So geometry is ok

5. Next step:
esxcli storage core path list

unknown.vmhba2-unknown.2:0-naa.600605b0037e874016c58d362843a979

   UID: unknown.vmhba2-unknown.2:0-naa.600605b0037e874016c58d362843a979

   Runtime Name: vmhba2:C2:T0:L0

   Device: naa.600605b0037e874016c58d362843a979

   Device Display Name: Local LSI Disk (naa.600605b0037e874016c58d362843a979)

   Adapter: vmhba2

   Channel: 2

   Target: 0

   LUN: 0

   Plugin: NMP

   State: active

   Transport: parallel

   Adapter Identifier: unknown.vmhba2

   Target Identifier: unknown.2:0

   Adapter Transport Details: Unavailable or path is unclaimed

   Target Transport Details: Unavailable or path is unclaimed

 

Seems to be all good


6. esxcfg-scsidevs -l –m
naa.600605b0037e874016c58d362843a979

   Device Type: Direct-Access

   Size: 6861696 MB

   Display Name: Local LSI Disk (naa.600605b0037e874016c58d362843a979)

   Multipath Plugin: NMP

   Console Device: /vmfs/devices/disks/naa.600605b0037e874016c58d362843a979

   Devfs Path: /vmfs/devices/disks/naa.600605b0037e874016c58d362843a979

   Vendor: LSI       Model: MR9260-8i         Revis: 2.70

   SCSI Level: 5  Is Pseudo: false Status: on

   Is RDM Capable: false Is Removable: false

   Is Local: true  Is SSD: false

   Other Names:

      vml.0200000000600605b0037e874016c58d362843a9794d5239323630

   VAAI Status: unsupported

 

I tried to reinstall ESXi but getting the same with my storage.

Thank you in advance.

VIX plug-in hangs at connect to server

$
0
0

Hi,

 

I just tried to use the VIX Plug-In for the first time to copy some files to a guest, but the Workflow run seems to hang at the action connectToServer. The workflows don't fail, they just keep running. I have some workflows running for almost two hours now. Unfortunately there aren't any errors in the vCO logfiles.

 

For testing I created a little workflow running only the connectToServer action. The connection doesn't work there neither. Has anyone experienced this before? I'm using vCO 4.2.1.

 

Thanks a lot.